Bitmain Antspace HW5 1200KW Dry-Wet Tower

Product: ANTSPACE HW5

Power Capacity: 1200 kW

Tower Type: Dry-Wet Tower

Miner Capacity: 210 MINER CAPACITY

Design: All In One

Benefits: Time, Space, and Money Saving

Feature: Brand new 40-feet container

NOTES:

1. The ANTSPACE HW5 is recommended to be used simultaneously with The ANTMINER S19 Hyd. / S21 Hyd. Series miner.

2. The pictures shown are for reference only; the final shipment version shall prevail.

  • Introducing ANTSPACE HW5 I: The Ultimate Mining Solution

    The ANTSPACE HW5, a powerful and efficient mining solution with a 1200 kW power capacity. Designed as a Dry-Wet Tower, this state-of-the-art unit supports up to 210 miners, making it a robust choice for high-demand mining operations. The all-in-one design of the ANTSPACE HW5 I is not only time-saving but also space and money-saving, providing significant advantages for large-scale deployments. Encased in a brand new 40-feet container, this solution combines efficiency and convenience, setting a new standard in the mining industry.

    img
  • img

Specifications Details for ANTSPACE HW5 in the tables below:

  Product Glance

  Value 

  Model   ANTSPACE HW5
  Version   V1
  Dimensions (l*w*h) (mm)   12192×2438×2896
  Miner capacity   210 units -S19 Hyd. &S21 Hyd. Series miner
  Container certification   China Classification Society Certification
  Safety certification   NFPA 79:2021

UL 508A:2018 R8.21

CSA C22.2 No. 14-18

ANSI/ISO 12100:2012

IEC 60204 Ed 5.1 2009

  Operating power(kW)   1062
  PUE(Power usage effectiveness)   1.032
  Input voltage and frequency   400V±5% 50/60Hz

 

Detailed Characteristics
  Shipping weight(T)   14
  Operating weight (T)   24
  Main switch of power distribution cabinets(A)   1200*2
  Rated current(A)   ≤986
  Rated Current per Miner (A)   ≤10
  Inlet cable   The inlet cables can withstand high-voltage of above   600V, with the following requirements:

L1 single core cable 600kcMil(300mm²)x4

L2 single core cable 600kcMil(300mm²)x4

L3 single core cable 600kcMil(300mm²)x4

N Single-core cable 600kcMil(300mm²)x4

PE single-core cable 500kcMil(240mm²)x2

  Flow rate(m³/h)   ≥85
  Quantity of ANTSPACE powered by one 2500kVA Transformer   2
Dry-Wet Tower
  Heat Dissipation Capacity (kW)   1200 kW
  Outlet Temperature @ 28℃ Wet Bulb Temperature   35℃
  Container Certification   China Classification Society Certification
  Operating Power (kW)   15~29
  Motor Rated Voltage and Frequency   400V±5% 50/60Hz
  Motor Rated Voltage and Frequency   DN40(Internal thread)
  Drain Pipe Interface   DN65(Internal thread)
  Noise Level @25℃, 15m   70 dBA
  Water Consumption (m³/h)   0.7~1.3m³/h

Points For Attention

  1   The cooling tower must be placed on a flat ground with a level of ±1 degree.
  2   The surface ground needs to be hardened and aimed to hold the ANTSPACE to be stable to withstand the load of at least 36 tons.
  3   The customers need to prepare a 20-ton crane to load and unload ANTSPACE and Cooling-tower.
  4   Stairs, walkway boards, transformers, cables, bridges, cable distribution boxes, and other external facilities are not included in ANTSPACE products.
  5   If you plan to store ANTSPACE units vertically on top of one another, please advise the BITMAIN sales team regarding the preferred opening direction for the door facing the air inlet of your ANTSAPCE unit. The door opens to the left by default.
  6   Leave at least 2 meters of air inlet space around the cooling tower.
  7   Operating elevation: lower than 2000 meters. If the height is more significant than 1000 meters and a 2500kVA transformer, the number of ANTSAPCE units installed in one ANTSPACE unit must be decreased by around 1%.
  8   Environmental requirements: Temperature: -25°C~40°C; Humidity 10%RH~90%RH; The ambient temperature requirement in high-humidity areas is not higher than 40°C. When the ambient temperature is lower than 0°C, the inlet and outlet shutters need to be closed, and the interior of the mining machine can only be started when it is heated to above 20°C.
  9   The ambient temperature of the ANTSPACE does not represent the ambient temperature of the mining machine.

Download

    Reviews

    There are no reviews yet.

    Only logged in customers who have purchased this product may leave a review.

    You may also like…

    • Bitmain Antspace HW5 1 Megawatt w/ Dry Tower

      Bitmain Antspace HW5 1 Megawatt w/ Dry Tower

      $130,000.00
      Add to cart
    • Bitmain Antspace HK3 V6 Liquid Cooling Container

      Bitmain Antspace HK3 V6 Liquid Cooling Container

      Price range: $100,100.00 through $188,000.00
      Select options